312
modifications
Aucun résumé des modifications |
Aucun résumé des modifications |
||
Ligne 10 : | Ligne 10 : | ||
]}, | ]}, | ||
{"id": "4008","title": "Anomalie de la qualité du tracé","type": "Texte","rang": "A","weight": "11","reponse": "","bareme": "0","popover": "","children": [ | {"id": "4008","title": "Anomalie de la qualité du tracé","type": "Texte","rang": "A","weight": "11","reponse": "","bareme": "0","popover": "","children": [ | ||
{"id": "4009","title": "Artefacts","type": "Checkbox","rang": "A","weight": "12","reponse": "","bareme": "1","popover": "<b>Artefact :</b> Un artefact est une anomalie du tracé lié à quelque chose d'externe à l'activité électrique cardiaque, ils sont très fréquents sur l'ECG. <br>(50Hz lié à une mauvaise isolation électrique de l'appareil ou du lit du patient, mouvements musculaires, électrodes mal collées…) <br><img src='/images/2/26/RR.png'><br>cf. <a href='/ECG_réalisation'>ECG réalisation</a>","children": []}, | {"id": "4009","title": "Artefacts","type": "Checkbox","rang": "A","weight": "12","reponse": "","bareme": "1","popover": "<b>Artefact :</b> Un artefact est une anomalie du tracé lié à quelque chose d'externe à l'activité électrique cardiaque, ils sont très fréquents sur l'ECG. <br>(50Hz lié à une mauvaise isolation électrique de l'appareil ou du lit du patient, mouvements musculaires, électrodes mal collées…) <br><img src='/images/2/26/RR.png'><br><br>cf. <a href='/ECG_réalisation'>ECG réalisation</a>","children": []}, | ||
{"id": "4010","title": "Inversion d'électrodes","type": "Checkbox","rang": "C","weight": "13","reponse": "","bareme": "2","popover": "Inversion d'électrode : elles sont fréquentes, surtout sur les dérivations périphériques. Un des moyens les plus simples de les détecter est de regarder si DI est négatif (onde P et QRS), mais selon le type d'inversion, les anomalies peuvent être variables.<br>cf. <a href='/ECG_réalisation'>ECG réalisation</a>","children": []}, | {"id": "4010","title": "Inversion d'électrodes","type": "Checkbox","rang": "C","weight": "13","reponse": "","bareme": "2","popover": "<b>Inversion d'électrode :</b> elles sont fréquentes, surtout sur les dérivations périphériques. <br>Un des moyens les plus simples de les détecter est de regarder si DI est négatif (onde P et QRS), mais selon le type d'inversion, les anomalies peuvent être variables.<br><br>cf. <a href='/ECG_réalisation'>ECG réalisation</a>","children": []}, | ||
{"id": "4011","title": "Amplitude différente de 25 mm/s et 1 mm = 0,1 mV ","type": "Checkbox","rang": "","weight": "14","reponse": "","bareme": "2","popover": "","children": []} | {"id": "4011","title": "Amplitude différente de 25 mm/s et 1 mm = 0,1 mV ","type": "Checkbox","rang": "","weight": "14","reponse": "","bareme": "2","popover": "","children": []} | ||
]}, | ]}, | ||
{"id": "4012","title": "Rythme ","type": "Texte","rang": "","weight": "15","reponse": "","bareme": "0","popover": "","children": [ | {"id": "4012","title": "Rythme ","type": "Texte","rang": "","weight": "15","reponse": "","bareme": "0","popover": "","children": [ | ||
{"id": "4013","title": "Rythme sinusal normal (Activité sinusale conduite aux ventricules)","type": "Checkbox","rang": "A","weight": "16","reponse": "","bareme": "4","popover": "Rythme sinusal normal : On parle de rythme sinusal normal lorsqu'il existe une activité sinusale régulière transmise à l'oreillette (Onde P positive en DII-DIII-aVF) et que cette activité est transmise au ventricule par le nœud atrio-ventriculaire (une onde P devant chaque QRS et un QRS après chaque onde P). En France, on raccourcit très souvent ce terme par rythme sinusal. <br>cf. <a href='/Rythme_sinusal'>Rythme sinusal</a>","children": []}, | {"id": "4013","title": "Rythme sinusal normal (Activité sinusale conduite aux ventricules)","type": "Checkbox","rang": "A","weight": "16","reponse": "","bareme": "4","popover": "<b>Rythme sinusal normal :</b> On parle de rythme sinusal normal lorsqu'il existe une activité sinusale régulière transmise à l'oreillette (Onde P positive en DII-DIII-aVF)<br> et que cette activité est transmise au ventricule par le nœud atrio-ventriculaire (une onde P devant chaque QRS et un QRS après chaque onde P). <br> En France, on raccourcit très souvent ce terme par rythme sinusal. <br><br>cf. <a href='/Rythme_sinusal'>Rythme sinusal</a>","children": []}, | ||
{"id": "4014","title": "Bradycardie / Trouble de conduction","type": "Checkbox","rang": "","weight": "17","reponse": "","bareme": "4","popover": "","children": [ | {"id": "4014","title": "Bradycardie / Trouble de conduction","type": "Checkbox","rang": "","weight": "17","reponse": "","bareme": "4","popover": "","children": [ | ||
{"id": "4015","title": "RR (ms) :","type": "Durée_RR","rang": "","weight": "18","reponse": "","bareme": "0","popover": "","children": []}, | {"id": "4015","title": "RR (ms) :","type": "Durée_RR","rang": "","weight": "18","reponse": "","bareme": "0","popover": "","children": []}, |