Aller au contenu

« Modèle de quizz ECG:Externe » : différence entre les versions

aucun résumé des modifications
Aucun résumé des modifications
Aucun résumé des modifications
Ligne 3 : Ligne 3 :
         "title": "Mesures sur le tracé","type": "Texte","popover": "","rang": "","weight": "1","reponse": "","bareme": "0","children": [
         "title": "Mesures sur le tracé","type": "Texte","popover": "","rang": "","weight": "1","reponse": "","bareme": "0","children": [
             {"id": "4001","emdl_id": "523","parent_id": "4000","title": "","type": "Boutons_Mesures","popover": "","rang": "","weight": "2","reponse": "","bareme": "0","children": []},
             {"id": "4001","emdl_id": "523","parent_id": "4000","title": "","type": "Boutons_Mesures","popover": "","rang": "","weight": "2","reponse": "","bareme": "0","children": []},
             {"id": "4002","emdl_id": "523","parent_id": "4000","title": "RR (ms) :","type": "Durée_RR","popover": "'''RR :''' c’est la mesure d’un cycle cardiaque qui se mesure le plus souvent de QRS à QRS.[[Fichier:RR.png]]\n\ncf. [[ECG mesures et calcul (fréquence, intervalles, amplitudes)]]","rang": "A","weight": "3","reponse": "","bareme": "0","children": []},
             {"id": "4002","emdl_id": "523","parent_id": "4000","title": "RR (ms) :","type": "Durée_RR","popover": "'''RR :''' c’est la mesure d’un cycle cardiaque qui se mesure le plus souvent de QRS à QRS.\n[[Fichier:RR.png]]\n\ncf. [[ECG mesures et calcul (fréquence, intervalles, amplitudes)]]","rang": "A","weight": "3","reponse": "","bareme": "0","children": []},
             {"id": "4003","emdl_id": "523","parent_id": "4000","title": "FC (bpm) :","type": "Fréquence","popover": "","rang": "","weight": "4","reponse": "","bareme": "0","children": []},
             {"id": "4003","emdl_id": "523","parent_id": "4000","title": "FC (bpm) :","type": "Fréquence","popover": "","rang": "","weight": "4","reponse": "","bareme": "0","children": []},
             {"id": "4004","emdl_id": "523","parent_id": "4000","title": "Durée PR (ms) :","type": "Durée_PR","popover": "'''PR :''' mesure du début de l’onde P au début du QRS, la norme est entre 120 et 200 ms.[[Fichier:PR1.png]]\n\ncf. [[ECG mesures et calcul (fréquence, intervalles, amplitudes)]]","rang": "A","weight": "5","reponse": "","bareme": "0","children": []},
             {"id": "4004","emdl_id": "523","parent_id": "4000","title": "Durée PR (ms) :","type": "Durée_PR","popover": "'''PR :''' mesure du début de l’onde P au début du QRS, la norme est entre 120 et 200 ms.\n[[Fichier:PR1.png]]\n\ncf. [[ECG mesures et calcul (fréquence, intervalles, amplitudes)]]","rang": "A","weight": "5","reponse": "","bareme": "0","children": []},
             {"id": "4005","emdl_id": "523","parent_id": "4000","title": "Durée QRS (ms) : ","type": "Durée_QRS","popover": "'''QRS :''' mesure du début du QRS à la fin du QRS, la norme est inférieure à 100 ms.[[Fichier:QRS.png]]\n\ncf. [[ECG mesures et calcul (fréquence, intervalles, amplitudes)]]","rang": "A","weight": "6","reponse": "","bareme": "0","children": []},
             {"id": "4005","emdl_id": "523","parent_id": "4000","title": "Durée QRS (ms) : ","type": "Durée_QRS","popover": "'''QRS :''' mesure du début du QRS à la fin du QRS, la norme est inférieure à 100 ms.\n[[Fichier:QRS.png]]\n\ncf. [[ECG mesures et calcul (fréquence, intervalles, amplitudes)]]","rang": "A","weight": "6","reponse": "","bareme": "0","children": []},
             {"id": "4006","emdl_id": "523","parent_id": "4000","title": "Durée QT (ms) : ","type": "Durée_QT","popover": "'''QT :''' mesure du début du QRS à la fin de l’onde T. La fin de l’onde T est définit par le croisement de la tangente de la pente descendante de l’onde T avec la ligne iso-électrique. La norme est <440 ms chez les femmes et <450 ms chez les hommes. [[Fichier:QT.png]]","rang": "A","weight": "7","reponse": "","bareme": "0","children": []},
             {"id": "4006","emdl_id": "523","parent_id": "4000","title": "Durée QT (ms) : ","type": "Durée_QT","popover": "'''QT :''' mesure du début du QRS à la fin de l’onde T. La fin de l’onde T est définit par le croisement de la tangente de la pente descendante de l’onde T avec la ligne iso-électrique. La norme est <440 ms chez les femmes et <450 ms chez les hommes. \n[[Fichier:QT.png]]","rang": "A","weight": "7","reponse": "","bareme": "0","children": []},
             {"id": "4007","emdl_id": "523","parent_id": "4000","title": "QT corrigé formule de Bazett (ms) : ","type": "QT_corrigé","popover": "'''QT corrigé :''' Le QT corrigé est un QT normalisé à la fréquence cardiaque car le QT se raccourcit lorsque la FC augmente. Formule de Bazett pour calculer le QT corrigé\n[[Fichier:QT1.png]]\nPour une FC à 60 bpm, le QT corrigé est identique au QT mesuré (on divise par 1).","rang": "A","weight": "8","reponse": "","bareme": "0","children": []}
             {"id": "4007","emdl_id": "523","parent_id": "4000","title": "QT corrigé formule de Bazett (ms) : ","type": "QT_corrigé","popover": "'''QT corrigé :''' Le QT corrigé est un QT normalisé à la fréquence cardiaque car le QT se raccourcit lorsque la FC augmente. Formule de Bazett pour calculer le QT corrigé\n[[Fichier:QT1.png]]\nPour une FC à 60 bpm, le QT corrigé est identique au QT mesuré (on divise par 1).","rang": "A","weight": "8","reponse": "","bareme": "0","children": []}
         ]},
         ]},
     {"id": "4008","emdl_id": "523","parent_id": null,
     {"id": "4008","emdl_id": "523","parent_id": null,
         "title": "Anomalie de la qualité du tracé","type": "Texte","popover": "","rang": "A","weight": "9","reponse": "","bareme": "0","children": [
         "title": "Anomalie de la qualité du tracé","type": "Texte","popover": "","rang": "A","weight": "9","reponse": "","bareme": "0","children": [
             {"id": "4009","emdl_id": "523","parent_id": "4008","title": "Artefacts","type": "Checkbox","popover": "<b>Artefact :</b> Un artefact est une anomalie du tracé lié à quelque chose d'externe à l'activité électrique cardiaque, ils sont très fréquents sur l'ECG. <br>(50Hz lié à une mauvaise isolation électrique de l'appareil ou du lit du patient, mouvements musculaires, électrodes mal collées…) <br><img src='/images/2/26/RR.png'><br><br>cf. <a href='/ECG_réalisation'>ECG réalisation</a>","rang": "A","weight": "10","reponse": "","bareme": "1","children": []},
             {"id": "4009","emdl_id": "523","parent_id": "4008","title": "Artefacts","type": "Checkbox","popover": "<b>Artefact :</b> Un artefact est une anomalie du tracé lié à quelque chose d'externe à l'activité électrique cardiaque, ils sont très fréquents sur l'ECG. <br>(50Hz lié à une mauvaise isolation électrique de l'appareil ou du lit du patient, mouvements musculaires, électrodes mal collées…)","rang": "A","weight": "10","reponse": "","bareme": "1","children": []},
             {"id": "4010","emdl_id": "523","parent_id": "4008","title": "Inversion d'électrodes","type": "Checkbox","popover": "<b>Inversion d'électrode :</b> elles sont fréquentes, surtout sur les dérivations périphériques. <br>Un des moyens les plus simples de les détecter est de regarder si DI est négatif (onde P et QRS), mais selon le type d'inversion, les anomalies peuvent être variables.<br><br>cf. <a href='/ECG_réalisation'>ECG réalisation</a>","rang": "C","weight": "11","reponse": "","bareme": "2","children": []},
             {"id": "4010","emdl_id": "523","parent_id": "4008","title": "Inversion d'électrodes","type": "Checkbox","popover": "<b>Inversion d'électrode :</b> elles sont fréquentes, surtout sur les dérivations périphériques. <br>Un des moyens les plus simples de les détecter est de regarder si DI est négatif (onde P et QRS), mais selon le type d'inversion, les anomalies peuvent être variables.<br><br>cf. <a href='/ECG_réalisation'>ECG réalisation</a>","rang": "C","weight": "11","reponse": "","bareme": "2","children": []},
             {"id": "4011","emdl_id": "523","parent_id": "4008","title": "Amplitude différente de 25 mm/s et 1 mm = 0,1 mV ","type": "Checkbox","popover": "","rang": "","weight": "12","reponse": "","bareme": "2","children": []}
             {"id": "4011","emdl_id": "523","parent_id": "4008","title": "Amplitude différente de 25 mm/s et 1 mm = 0,1 mV ","type": "Checkbox","popover": "","rang": "","weight": "12","reponse": "","bareme": "2","children": []}
Bureaucrates, enseignant, Administrateurs d’interface, patroller, patrouilleur, Administrateurs
62

modifications